Signal Processing Pipeline Specification
Every file inspected on MusicDetect Forensics undergoes four deterministic, reproducible DSP computations inside your browser:
- Multi-Frame Hann-Windowed FFT: We sample 48 evenly distributed windows across the full duration of the decoded PCM buffer, apply a symmetric Hann window (
0.5 * (1 - cos(2πk/(N-1)))), and compute an exact radix-2 Cooley-Tukey FFT (N = 2048). - Wiener Spectral Flatness (
1–12 kHz): Ratio of the geometric mean to arithmetic mean of bin power across1 kHz – 12 kHz(exp(mean(ln(P))) / mean(P)). - High-Frequency Energy Ratio (
>16 kHzvs4–12 kHz): Expresses total power above16 kHzrelative to mid-treble reference energy in decibels (10 * log10(E_hi / E_mid)). - Crest Factor & Stereo Pearson Correlation: Measures peak-to-RMS ratio (
20 * log10(peak / rms)) and cross-channel correlationsum(L*R) / sqrt(sum(L^2) * sum(R^2)).
Known False-Positive & False-Negative Scenarios
Honest forensics demands documenting failure modes clearly:
- False Positives (Human music flagged): 128 kbps MP3/AAC transcodes, vinyl/cassette lo-fi filters, deliberate telephone/radio EQ, or heavily brickwalled EDM masters can exhibit
< -38 dBabove 16 kHz or< 8 dBcrest factor. - False Negatives (AI music appearing clean): High-sample-rate AI generations that are subsequently mastered through analog tape saturation or layered with live acoustic overdubs can populate
16–20 kHzharmonics naturally.
Because of these physical realities, treat client-side telemetry as first-pass acoustic evidence, and pair with our Pro Deep-Model Check plus human stem verification for binding decisions.